Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 01-068-2450 (010682450) |
NCB Code | USA (01) |
Manufacturer | Simmonds Precision Products Inc, Struthers Dunn Inc, Boeing Company The, Sprague Products Co, Military Specifications, Trw Limited, Sprague Electric Co, Lockheed Martin Corporation, Interstate Electronics Corporation, Heico Ohmite Llc, Shallcross Inc, Vishay Dale Electronics Inc, Army United States Department Of The |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
495048T212 | simmonds precision products inc | resistor fixed wire wound induct | RFQ |
1000S300-1 | struthers dunn inc | resistor fixed wire wound induct | RFQ |
443-0955-335 | boeing company the | resistor fixed wire wound induct | RFQ |
240E301J | sprague products co | resistor fixed wire wound induct | RFQ |
443-1344-007 | boeing company the | resistor fixed wire wound induct | RFQ |
MIL-R-39007/8 | military specifications | resistor fixed wire wound induct | RFQ |
BWH301J | trw limited | resistor fixed wire wound induct | RFQ |
240E3015 | sprague electric co | resistor fixed wire wound induct | RFQ |
RW70U3000F | lockheed martin corporation | resistor fixed wire wound induct | RFQ |
1009SM007 | struthers dunn inc | resistor fixed wire wound induct | RFQ |
499-052-037 | interstate electronics corporation | resistor fixed wire wound induct | RFQ |
RW70U301J | military specifications | resistor fixed wire wound induct | RFQ |
222S300R0J | heico ohmite llc | resistor fixed wire wound induct | RFQ |
RWR80S3010FM | military specifications | resistor fixed wire wound induct | RFQ |
RR80S3010FM | military specifications | resistor fixed wire wound induct | RFQ |
443-1849-335 | boeing company the | resistor fixed wire wound induct | RFQ |
240E3015 | sprague products co | resistor fixed wire wound induct | RFQ |
RWR80S3010FP | military specifications | resistor fixed wire wound induct | RFQ |
B3-301J | shallcross inc | resistor fixed wire wound induct | RFQ |
RW70U3010F | military specifications | resistor fixed wire wound induct | RFQ |
RW70U3000F | military specifications | resistor fixed wire wound induct | RFQ |
RWR80S3000FM | military specifications | resistor fixed wire wound induct | RFQ |
RWR80S3010FR | military specifications | resistor fixed wire wound induct | RFQ |
RS1A300R0F | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
AGS3-65-007 | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
10526693 | army united states department of the | resistor fixed wire wound induct | RFQ |
G 3 80 301 1 | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
RWR80S3010FS | military specifications | resistor fixed wire wound induct | RFQ |
EGS-3-40-335 | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
PR49S18-335 | shallcross inc | resistor fixed wire wound induct | RFQ |
MIL-PRF-39007/8 | military specifications | resistor fixed wire wound induct | RFQ |
PR49W5032-007 | shallcross inc | resistor fixed wire wound induct | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0 TO 20.0 |
AAPP | ELECTRICAL RESISTANCE | 301.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
AARE | REACTANCE CHARACTERISTIC | INDUCTIVE |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.094 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.406 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 2.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CSCF | TERMINAL TYPE | WIRE LEAD |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLEC |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-39007/8 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5905-01-068-2450, 5905010682450 | ||||
5930-01-024-7616 (5930010247616) | 5935-01-207-1630 (5935012071630) | 5930-00-522-3346 (5930005223346) | 5985-01-615-6045 (5985016156045) | |
5910-00-805-1017 (5910008051017) | 5962-01-297-8133 (5962012978133) | 5935-01-108-9409 (5935011089409) | 5910-01-082-8261 (5910010828261) | |
5930-01-681-7491 (5930016817491) | 5930-01-322-8532 (5930013228532) | 5935-00-755-3452 (5935007553452) | 5985-01-676-2667 (5985016762667) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.