Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 01-137-0081 (011370081) |
NCB Code | USA (01) |
Manufacturer | Military Specifications, Trw Limited, Agilent Technologies Inc, Hewlett-Packard Company, Meggitt International Ltd, Vishay Dale Electronics Inc, Raytheon Company, Ward Leonard Electric Company Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
RWR69SR511FM | military specifications | resistor fixed wire wound induct | RFQ |
MIL-R-39007/11 | military specifications | resistor fixed wire wound induct | RFQ |
BW20R51J | trw limited | resistor fixed wire wound induct | RFQ |
0811-3079 | agilent technologies inc | resistor fixed wire wound induct | RFQ |
0811-3079 | hewlett-packard company | resistor fixed wire wound induct | RFQ |
SPH-0R51-5PCT | trw limited | resistor fixed wire wound induct | RFQ |
0200-4350 | meggitt international ltd | resistor fixed wire wound induct | RFQ |
RS2BX000ER5110F | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
BWH0-51-5PCT | trw limited | resistor fixed wire wound induct | RFQ |
RWR69SR511FR | military specifications | resistor fixed wire wound induct | RFQ |
4171530-875 | raytheon company | resistor fixed wire wound induct | RFQ |
RWR89SR511FM | military specifications | resistor fixed wire wound induct | RFQ |
MIL-PRF-39007/11 | military specifications | resistor fixed wire wound induct | RFQ |
3XM0R50J | ward leonard electric company inc | resistor fixed wire wound induct | RFQ |
RW79UR511F | military specifications | resistor fixed wire wound induct | RFQ |
RWR89SR511FS | military specifications | resistor fixed wire wound induct | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -90.0 TO 90.0 |
AAPP | ELECTRICAL RESISTANCE | 0.511 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.156 INCHES MINIMUM AND 0.218 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.498 INCHES MINIMUM AND 0.622 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CBME | CUBIC MEASURE | 0.015 CUBIC INCHES |
CSCF | TERMINAL TYPE | WIRE LEAD |
PKWT | UNPACKAGED UNIT WEIGHT | 3.0 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39007/11 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5905-01-137-0081, 5905011370081 | ||||
5999-01-196-8879 (5999011968879) | 5970-00-488-9670 (5970004889670) | 5945-01-477-0491 (5945014770491) | 5999-01-364-2930 (5999013642930) | |
5996-01-452-4386 (5996014524386) | 5945-00-260-1626 (5945002601626) | 5998-01-130-0814 (5998011300814) | 5905-00-557-4486 (5905005574486) | |