MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.370 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.421 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.155 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 30.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 25.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 10.7 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.2 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 15.0 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.2 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 21.4 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 25.0 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 28.5 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.2 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 6TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CBME | CUBIC MEASURE | 0.008 CUBIC INCHES |
CQWD | ZERO POWER RESISTANCE | 15.000 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
SFTT | SURFACE TREATMENT | SOLDER TERMINAL |
STYL | STYLE DESIGNATOR | ROD |