Item Name | Resistor Variable Nonwire Wound |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 01-207-6435 (012076435) |
NCB Code | USA (01) |
Manufacturer | Lockheed Martin Corporation, Military Specifications, Raytheon Company, Harris Corporation, Rockwell Collins Aerospace, Rockwell Automation Ltd, Beckman Coulter Inc, Gould Instrument Systems Inc, Allied Signal Inc, Hewlett-Packard Company, L 3 Communications Corporation, Vernitron Corp, Ferro Corp, Boeing Company The, Bourns Instruments Inc, Northrop Grumman Systems Corporation, Thales Defense And Security Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
548-00HS50K | lockheed martin corporation | resistor variable nonwire wound | RFQ |
MIL-R-39035/2 | military specifications | resistor variable nonwire wound | RFQ |
997966-12 | raytheon company | resistor variable nonwire wound | RFQ |
R30-0008-503 | harris corporation | resistor variable nonwire wound | RFQ |
RJR24FW503P | military specifications | resistor variable nonwire wound | RFQ |
380-1080-301 | rockwell collins aerospace | resistor variable nonwire wound | RFQ |
85W503 | rockwell automation ltd | resistor variable nonwire wound | RFQ |
538424-30 | raytheon company | resistor variable nonwire wound | RFQ |
68W50K | beckman coulter inc | resistor variable nonwire wound | RFQ |
269085-503 | gould instrument systems inc | resistor variable nonwire wound | RFQ |
645-FW503-M | allied signal inc | resistor variable nonwire wound | RFQ |
2100-3096 | hewlett-packard company | resistor variable nonwire wound | RFQ |
RJR24HW503R | military specifications | resistor variable nonwire wound | RFQ |
G-876-24FW503P | l 3 communications corporation | resistor variable nonwire wound | RFQ |
G368049-12 | raytheon company | resistor variable nonwire wound | RFQ |
752-208-50K | vernitron corp | resistor variable nonwire wound | RFQ |
68WR50K | ferro corp | resistor variable nonwire wound | RFQ |
444-0504-139 | boeing company the | resistor variable nonwire wound | RFQ |
850-208-50K0MP0R | vernitron corp | resistor variable nonwire wound | RFQ |
380-1080-301 | bourns instruments inc | resistor variable nonwire wound | RFQ |
MIL-PRF-39035/2 | military specifications | resistor variable nonwire wound | RFQ |
MT2W503 | rockwell automation ltd | resistor variable nonwire wound | RFQ |
924733-0013 | northrop grumman systems corporation | resistor variable nonwire wound | RFQ |
869027-3313 | thales defense and security inc | resistor variable nonwire wound | RFQ |
RJR24FW503R | military specifications | resistor variable nonwire wound | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ABJT | TERMINAL LENGTH | 0.300 INCHES MINIMUM |
ABWV | SHAFT DIAMETER | 0.075 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.080 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.420 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.170 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.375 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND,SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 10800.0 MAXIMUM |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AXGY | MOUNTING METHOD | TERMINAL |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
CBME | CUBIC MEASURE | 0.270 CUBIC INCHES |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.000 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 10800.0 MAXIMUM |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CQTM | TERMINAL LOCATION | REAR END |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
CXHN | SHAFT BEARING TYPE | SLEEVE |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39035 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39035/2 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5905-01-207-6435, 5905012076435 | ||||
5930-01-024-7616 (5930010247616) | 5935-01-207-1630 (5935012071630) | 5930-00-522-3346 (5930005223346) | 5985-01-615-6045 (5985016156045) | |
5910-00-805-1017 (5910008051017) | 5962-01-297-8133 (5962012978133) | 5935-01-108-9409 (5935011089409) | 5910-01-082-8261 (5910010828261) | |
5930-01-681-7491 (5930016817491) | 5930-01-322-8532 (5930013228532) | 5935-00-755-3452 (5935007553452) | 5985-01-676-2667 (5985016762667) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote