MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.125 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.015 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.90 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -10.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 115.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 30.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.30544 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 103.156 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.38948 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 23.3536 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 328.492 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 37.1214 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 413.28 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 521.52 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.77402 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 756.86 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.2 TO 10.2 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.6 TO 2.6 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -4.3 TO 4.3 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.3 TO 5.3 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.3 TO 6.3 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.5 TO 7.5 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.6 TO 7.6 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.1 TO 8.1 9TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.9 TO 8.9 10TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | UNINCLOSED |
CQWD | ZERO POWER RESISTANCE | 8.200 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -2.0 TO 2.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
SFTT | SURFACE TREATMENT | SOLDER TERMINAL |
STYL | STYLE DESIGNATOR | BEAD |
TEST | TEST DATA DOCUMENT | 03640-6135475 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |