MRC | Criteria | Characteristic |
---|
ABKW | OVERALL HEIGHT | 0.695 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.120 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.595 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.235 INCHES MINIMUM AND 1.245 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 2000.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.840 INCHES MINIMUM AND 0.860 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -20.0 TO 71.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 477.275 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 477.575 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 100.0 OHMS 1ST BAND PASS 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 100.0 OHMS 2ND BAND PASS 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 168.0 KILOHMS 1ST BAND PASS 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 168.0 KILOHMS 2ND BAND PASS 2ND FUNCTION |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 7 TERMINAL |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 1ST BAND PASS 1ST FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 2ND BAND PASS 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 476.475 KILOHERTZ 1ST BAND PASS AND 477.25 KILOHERTZ 1ST BAND PASS AND 477.30 KILOHERTZ 1ST BAND PASS AND 478.075 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 476.775 KILOHERTZ 2ND BAND PASS AND 477.55 KILOHERTZ 2ND BAND PASS AND 477.60 KILOHERTZ 2ND BAND PASS AND 478.375 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 477.25 KILOHERTZ 1ST BAND PASS AND 477.30 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 477.55 KILOHERTZ 2ND BAND PASS AND 477.60 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 1ST BAND PASS AND 1.5 MAXIMUM 1ST BAND PASS 1ST FUNCTION1.5 MAXIMUM 1ST BAND PASS AND 30.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 2ND BAND PASS AND 1.5 MAXIMUM 2ND BAND PASS 2ND FUNCTION1.5 MAXIMUM 2ND BAND PASS AND 30.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
FEAT | SPECIAL FEATURES | UNPACKAGED UNIT WEIGHT: GM42.000 |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |