Database of Filter Radio Frequency Interfere Under NSN (5915011575211) 5915-01-157-5211 Parts

Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 01-157-5211 (011575211)
NCB Code USA (01)
Manufacturer Ems Development Corporation, Raytheon Company, Inspektorat Wsparcia Sil Zbrojnych, Corcom Inc
Part Number Manufacturer Item Name RFQ
RF9009-5 ems development corporation filter radio frequency interfere RFQ
929096-5 raytheon company filter radio frequency interfere RFQ
5915PL0726424 inspektorat wsparcia sil zbrojnych filter radio frequency interfere RFQ
NF21154-5 corcom inc filter radio frequency interfere RFQ

Technical Characteristics of NSN 5915011575211

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH2.430 INCHES NOMINAL
ABKWOVERALL HEIGHT2.830 INCHES NOMINAL
ADAQBODY LENGTH2.180 INCHES NOMINAL
ADATBODY WIDTH2.180 INCHES NOMINAL
ADAUBODY HEIGHT2.580 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.880 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ100.0 TO 350.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.880 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-28.0 TO 70.0 DEG CELSIUS
AFSVAVERAGE LIFE RATING IN HOURS92000.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.4 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.4 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.4 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE49956
AHBPINPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 0.5 AND 1.0 AND 10.0 AND 50.0
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS3.0 AND 5.0 AND 30.0 AND 43.0 AND 60.0
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CBBLFEATURES PROVIDEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 TURRET OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQJXNOMINAL THREAD SIZE0.112 INCHES
CQRGBODY MATERIALALUMINUM
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE322.0 VOLTS AT SEA LEVEL
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURESFOUR FILTERED FUNCTIONS,ONE UNFILTERED FUNCTION
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES

Relevant Components for NSN - 5915-01-157-5211, 5915011575211
5975-00-900-5000 (5975009005000) 5915-00-509-2939 (5915005092939) 5995-01-622-9763 (5995016229763) 5930-00-188-2156 (5930001882156)
5998-01-494-7223 (5998014947223) 5905-01-529-9031 (5905015299031) 5950-00-519-4719 (5950005194719) 5998-01-070-9399 (5998010709399)
5935-01-007-6384 (5935010076384) 5940-01-609-5218 (5940016095218) 5998-00-781-1392 (5998007811392) 5925-01-340-5534 (5925013405534)