Buy Military Ground Vehicle Parts is a one-stop shop for NSN 5925-00-476-7997 supplies, our selection currently featuring popular part numbers like AP112-1-42-302, AP112-485-112, 533257-112, and others. With everything featured on our catalog being available for purchase today, do not hesitate to begin exploring options while utilizing provided listing resources to narrow your search. Alongside simplifying the process of locating NSN 5925-00-476-7997 parts of interest, we have also streamlined the quotation process with our online Request for Quote (RFQ) forms. By filling out and submitting a request on our website with information on your needs, our staff will be able to provide you with fully customized purchasing options for your consideration.
We aim to provide the most reliable procurement options for our customers, following a strict sourcing policy that ensures that all NSN 5925-00-476-7997 parts we stock can be traced back to a trusted manufacturer. Furthermore, customers can rest easy knowing that our staff will work closely with them to find options that meet any time constraints or purchasing options, with consultation offered for any expedited delivery requests. With all of this in mind, be sure to get in contact with us at any time if you have any inquiries or purchasing requests!
Item Name | Circuitbreaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-476-7997 (004767997) |
NCB Code | USA (00) |
Manufacturer | Sensata Technologies Inc, Raytheon Company |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
AP112-1-42-302 | sensata technologies inc | circuitbreaker | RFQ |
AP112-485-112 | sensata technologies inc | circuitbreaker | RFQ |
533257-112 | raytheon company | circuitbreaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND |
CQXF | Inclosure Protection Type For Which Designed | HERMETICALLY SEALED AND |
BBRJ | Special Handling Feature | MAGNETIC |
MRC | Decoded Requirement | Clear Text Reply |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
AEFP | Nonturn Device Radius | 0.656 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
TTQY | Terminal Type And Quantity | 6 WIRE HOOK |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEFP | Nonturn Device Radius | 0.594 INCHES MINIMUM AND |
AEFQ | Nonturn Device Length | 0.063 INCHES MINIMUM AND |
AEFS | Nonturn Device Diameter | 0.171 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT POLE TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
AAJE | Thread Pitch Diameters | 0.3503 TO 0.3537 INCHES |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
AEFN | Nonturn Device Location | AT 3 OCLOCK AND |
AEFN | Nonturn Device Location | AT 9 OCLOCK |
AEFQ | Nonturn Device Length | 0.125 INCHES MAXIMUM |
AEFS | Nonturn Device Diameter | 0.109 INCHES MINIMUM AND |
ADAQ | Body Length | 1.500 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.375 INCHES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.656 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.844 INCHES MINIMUM AND |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
ADAT | Body Width | 1.875 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.900 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
THSD | Thread Series Designator | UNEF |
CQXF | Inclosure Protection Type For Which Designed | VIBRATION RESISTANT |
Relevant Components for NSN - 5925-00-476-7997, 5925004767997 | ||||
5930-01-228-1670 (5930012281670) | 5930-01-526-7841 (5930015267841) | 5962-00-734-6288 (5962007346288) | 5910-00-725-0394 (5910007250394) | |
5955-01-345-5019 (5955013455019) | 5999-00-185-5864 (5999001855864) | 5962-01-605-4088 (5962016054088) | 5985-00-833-8063 (5985008338063) | |
5930-01-583-6734 (5930015836734) | 5995-01-252-5806 (5995012525806) | 5910-01-646-1244 (5910016461244) | 5995-01-407-6159 (5995014076159) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote