Buy Military Ground Vehicle Parts is a one-stop shop for NSN 5925-00-723-4912 supplies, our selection currently featuring popular part numbers like DMS83059, 3XAM17-15-115VAC400C55, 3XAM17-15-208V24, 3XAM17-15-208AC400-55, 17-03987-1, and others. With everything featured on our catalog being available for purchase today, do not hesitate to begin exploring options while utilizing provided listing resources to narrow your search. Alongside simplifying the process of locating NSN 5925-00-723-4912 parts of interest, we have also streamlined the quotation process with our online Request for Quote (RFQ) forms. By filling out and submitting a request on our website with information on your needs, our staff will be able to provide you with fully customized purchasing options for your consideration.
We aim to provide the most reliable procurement options for our customers, following a strict sourcing policy that ensures that all NSN 5925-00-723-4912 parts we stock can be traced back to a trusted manufacturer. Furthermore, customers can rest easy knowing that our staff will work closely with them to find options that meet any time constraints or purchasing options, with consultation offered for any expedited delivery requests. With all of this in mind, be sure to get in contact with us at any time if you have any inquiries or purchasing requests!
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-723-4912 (007234912) |
NCB Code | USA (00) |
Manufacturer | Dla Land And Maritime, Eaton Corporation, Lockheed Martin Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
DMS83059 | dla land and maritime | circuit breaker | RFQ |
3XAM17-15-115VAC400C55 | eaton corporation | circuit breaker | RFQ |
3XAM17-15-208V24 | eaton corporation | circuit breaker | RFQ |
3XAM17-15-208AC400-55 | eaton corporation | circuit breaker | RFQ |
17-03987-1 | lockheed martin corporation | circuit breaker | RFQ |
DMS 83059B | dla land and maritime | circuit breaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.120 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.263 INCHES MINIMUM AND 2.283 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,AND THREE LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3.000 MINIMUM AT 200 PCT AND 8.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
ADAQ | BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 208.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
Relevant Components for NSN - 5925-00-723-4912, 5925007234912 | ||||
5945-01-123-8307 (5945011238307) | 5940-01-609-6503 (5940016096503) | 5998-01-163-2401 (5998011632401) | 5905-00-850-0094 (5905008500094) | |
5910-01-049-2188 (5910010492188) | 5975-99-301-9558 (5975993019558) | 5905-00-442-9377 (5905004429377) | 5945-00-513-0926 (5945005130926) | |
5945-00-909-3564 (5945009093564) | 5910-00-281-0147 (5910002810147) | 5905-00-131-4061 (5905001314061) | 5998-00-103-0209 (5998001030209) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote