Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-067-5870 (010675870) |
NCB Code | USA (01) |
Manufacturer | Eaton Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
HE2-B3-1-6P | eaton corporation | circuit breaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AKPX | Pole Quantity | 2 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 6.0 AMPERES DC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES DC FIRST LOCATION |
ABXD | Bushing Length | 0.375 INCHES NOMINAL |
AJWX | Mounting Surface To Terminal End Distance | 1.700 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 50.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 120.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
THSD | Thread Series Designator | UNEF |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | THD BUSHING W/PANEL SEAL |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.825 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
PKWT | Unpackaged Unit Weight | 2.100 OUNCES |
CMLP | Thread Quantity Per Inch | 32 |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 500.0 DC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRP | Ultimate Trip Time Per Pole In Seconds | 0.060 NOMINAL ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 WIRE HOOK |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT AND FUNGUS RESISTANT AND EXPLOSION RESISTANT |
Relevant Components for NSN - 5925-01-067-5870, 5925010675870 | ||||
5975-00-900-5000 (5975009005000) | 5915-00-509-2939 (5915005092939) | 5995-01-622-9763 (5995016229763) | 5930-00-188-2156 (5930001882156) | |
5998-01-494-7223 (5998014947223) | 5905-01-529-9031 (5905015299031) | 5950-00-519-4719 (5950005194719) | 5998-01-070-9399 (5998010709399) | |
5935-01-007-6384 (5935010076384) | 5940-01-609-5218 (5940016095218) | 5998-00-781-1392 (5998007811392) | 5925-01-340-5534 (5925013405534) | |