Buy Military Ground Vehicle Parts is a one-stop shop for NSN 5925-01-485-9638 supplies, our selection currently featuring popular part numbers like MIL-PRF-39019/3, M39019/03-055S, M39019/03-248S, 10047, 927439-0013, and others. With everything featured on our catalog being available for purchase today, do not hesitate to begin exploring options while utilizing provided listing resources to narrow your search. Alongside simplifying the process of locating NSN 5925-01-485-9638 parts of interest, we have also streamlined the quotation process with our online Request for Quote (RFQ) forms. By filling out and submitting a request on our website with information on your needs, our staff will be able to provide you with fully customized purchasing options for your consideration.
We aim to provide the most reliable procurement options for our customers, following a strict sourcing policy that ensures that all NSN 5925-01-485-9638 parts we stock can be traced back to a trusted manufacturer. Furthermore, customers can rest easy knowing that our staff will work closely with them to find options that meet any time constraints or purchasing options, with consultation offered for any expedited delivery requests. With all of this in mind, be sure to get in contact with us at any time if you have any inquiries or purchasing requests!
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-485-9638 (014859638) |
NCB Code | USA (01) |
Manufacturer | Military Specifications, Ap Labs Inc, Northrop Grumman Systems Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
MIL-PRF-39019/3 | military specifications | circuit breaker | RFQ |
M39019/03-055S | military specifications | circuit breaker | RFQ |
M39019/03-248S | military specifications | circuit breaker | RFQ |
10047 | ap labs inc | circuit breaker | RFQ |
927439-0013 | northrop grumman systems corporation | circuit breaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 1.828 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
AAQL | Body Style | |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
CPRH | Circuit Protection Type | REVERSE PHASE ALL LOCATIONS |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-39019/3 GOVERNMENT SPECIFICATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 4 SCREW |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF AND FUNGUS PROOF AND HERMETICALLY SEALED AND MOISTURE PROOF |
MRC | Decoded Requirement | Clear Text Reply |
TEST | Test Data Document | 81349-MIL-PRF-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
Relevant Components for NSN - 5925-01-485-9638, 5925014859638 | ||||
5945-01-123-8307 (5945011238307) | 5940-01-609-6503 (5940016096503) | 5998-01-163-2401 (5998011632401) | 5905-00-850-0094 (5905008500094) | |
5910-01-049-2188 (5910010492188) | 5975-99-301-9558 (5975993019558) | 5905-00-442-9377 (5905004429377) | 5945-00-513-0926 (5945005130926) | |
5945-00-909-3564 (5945009093564) | 5910-00-281-0147 (5910002810147) | 5905-00-131-4061 (5905001314061) | 5998-00-103-0209 (5998001030209) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.