Item Name | Switch Thermostatic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-068-8208 (000688208) |
NCB Code | USA (00) |
Manufacturer | Detroit Switch Inc, Gaylord Industries Inc, American Standard Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
222-10NNM2221628 | detroit switch inc | switch thermostatic | RFQ |
222-2062-NH2 | gaylord industries inc | switch thermostatic | RFQ |
222-10NNM2221682 | american standard inc | switch thermostatic | RFQ |
TS-1420 | detroit switch inc | switch thermostatic | RFQ |
222-10NH2-2221628 | detroit switch inc | switch thermostatic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.375 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.546 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.625 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDU | INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.500 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | BULB |
AWTN | OPERATING TEMP RATING | 195.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | OBTUSE TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.4 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 90.00 TO 180.00 ACTUATION POINT DEGREES FAHRENHEIT AND 90.00/180.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL FOURTH VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | RECTANGULAR |
Relevant Components for NSN - 5930-00-068-8208, 5930000688208 | ||||
5999-01-196-8879 (5999011968879) | 5970-00-488-9670 (5970004889670) | 5945-01-477-0491 (5945014770491) | 5999-01-364-2930 (5999013642930) | |
5996-01-452-4386 (5996014524386) | 5945-00-260-1626 (5945002601626) | 5998-01-130-0814 (5998011300814) | 5905-00-557-4486 (5905005574486) | |
5935-01-689-9407 (5935016899407) | 5980-01-504-2998 (5980015042998) | 5935-00-644-6464 (5935006446464) | 5995-01-277-3853 (5995012773853) | |