Item Name | Switch Thermostatic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-259-3362 (002593362) |
NCB Code | USA (00) |
Manufacturer | Colt Industries Inc, Detroit Switch Inc, Inspektorat Wsparcia Sil Zbrojnych, Kato Engineering Inc, American Standard Inc, Military Specifications |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
ICN31A11 | colt industries inc | switch thermostatic | RFQ |
222-32NL1-222347 | detroit switch inc | switch thermostatic | RFQ |
5930PL0645045 | inspektorat wsparcia sil zbrojnych | switch thermostatic | RFQ |
514-00300-25 | kato engineering inc | switch thermostatic | RFQ |
222-347 | american standard inc | switch thermostatic | RFQ |
IC/N31A11 | military specifications | switch thermostatic | RFQ |
MIL-S-16032 | military specifications | switch thermostatic | RFQ |
222347 | detroit switch inc | switch thermostatic | RFQ |
99-9-F821212-2 | colt industries inc | switch thermostatic | RFQ |
IC/N31A11 | detroit switch inc | switch thermostatic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.969 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.813 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 120.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.750 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AWTN | OPERATING TEMP RATING | -273.1 DEG CELSIUS MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BASE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 100.00 TO 225.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
STYL | STYLE DESIGNATOR | RECTANGULAR |
TEST | TEST DATA DOCUMENT | 81349-MILS16032 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
Relevant Components for NSN - 5930-00-259-3362, 5930002593362 | ||||
5999-01-196-8879 (5999011968879) | 5970-00-488-9670 (5970004889670) | 5945-01-477-0491 (5945014770491) | 5999-01-364-2930 (5999013642930) | |
5996-01-452-4386 (5996014524386) | 5945-00-260-1626 (5945002601626) | 5998-01-130-0814 (5998011300814) | 5905-00-557-4486 (5905005574486) | |
5935-01-689-9407 (5935016899407) | 5980-01-504-2998 (5980015042998) | 5935-00-644-6464 (5935006446464) | 5995-01-277-3853 (5995012773853) | |