MRC | Criteria | Characteristic |
---|
AASA | THREAD LENGTH | 0.380 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
ABHP | OVERALL LENGTH | 7.120 INCHES MAXIMUM |
ABNB | FIRST FLAT LENGTH | 0.437 INCHES NOMINAL 2ND ACTUATOR |
ABNB | FIRST FLAT LENGTH | 0.470 INCHES NOMINAL 1ST ACTUATOR |
ABNC | FLAT HEIGHT | 0.094 INCHES NOMINAL 2ND ACTUATOR |
ABNC | FLAT HEIGHT | 0.210 INCHES NOMINAL 1ST ACTUATOR |
ABWV | SHAFT DIAMETER | 0.125 INCHES NOMINAL 2ND ACTUATOR |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL 1ST ACTUATOR |
ABXF | SHAFT LENGTH | 0.870 INCHES NOMINAL 1ST ACTUATOR |
ABXF | SHAFT LENGTH | 1.500 INCHES NOMINAL 2ND ACTUATOR |
ADAV | OVERALL DIAMETER | 2.000 INCHES MAXIMUM |
AFBH | INDIVIDUAL SECTION QUANTITY | 10 |
AFDC | NONTURN DEVICE TYPE | SLOTTED BUSHING AT 3:00 OCLOCK |
AFGA | OPERATING TEMP RANGE | -65.0 TO 125.0 DEG CELSIUS |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
CQRQ | SHAFT FLAT/SLOT ANGULAR LOCATION | 0.0 DEGREES FROM NONTURN DEVICE 1ST ACTUATOR |
CQRQ | SHAFT FLAT/SLOT ANGULAR LOCATION | 0.0 DEGREES FROM NONTURN DEVICE 2ND ACTUATOR |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 12 2ND ACTUATOR |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 24 1ST ACTUATOR |
CRSJ | SHAFT TYPE | ROUND,FLATTED 2ND ACTUATOR |
CRSJ | SHAFT TYPE | ROUND,HOLLOWED,FLATTED 1ST ACTUATOR |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION REAR |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 15.0 DEGREES 1ST ACTUATOR |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 15.0 DEGREES 2ND ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
STYL | STYLE DESIGNATOR | TAP,CIRCULAR,BUSHING MOUNT |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
THSD | THREAD SERIES DESIGNATOR | UNS SINGLE MOUNTING FACILITY |