MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2A |
ABHP | OVERALL LENGTH | 1.938 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.142 INCHES MINIMUM AND 0.157 INCHES MAXIMUM |
AFQK | DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 0.812 INCHES MINIMUM AND 0.843 INCHES MAXIMUM |
AFQR | THREADED DEVICE TYPE | COUPLING FACILITY |
AFQW | MATING END QUANTITY | 1 |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 28-20 SINGLE MATING END |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 500.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 700.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AFRN | POLARIZATION METHOD | KEYWAY OR MULTIPLE KEYWAY |
AFRP | INSERT POSITION IN DEG | 80.0 |
CMLP | THREAD QUANTITY PER INCH | 18 |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
CQYH | CONTACT SURFACE TREATMENT | GOLD SINGLE MATING END ALL CONTACT GROUPINGS AND SILVER SINGLE MATING END ALL CONTACT GROUPINGS |
CQZG | INSERT MATERIAL | RUBBER SINGLE MATING END |
CSCF | TERMINAL TYPE | SOLDER WELL SINGLE MATING END ALL CONTACT GROUPINGS |
CSPT | SHELL MATERIAL | ALUMINUM ALLOY |
CXCL | INCLUDED CONTACT TYPE | ROUND PIN SINGLE MATING END ALL CONTACT GROUPINGS |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD AND CONTACT SURFACES SILVER |
PMWT | PRECIOUS MATERIAL AND WEIGHT | 0.050 GOLD GRAINS,TROY AND 0.050 SILVER GRAINS,TROY |
PRMT | PRECIOUS MATERIAL | GOLD AND SILVER |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-5015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS3102 GOVERNMENT STANDARD |
AAJF | THREAD DIRECTION | RIGHT-HAND |
AAQL | BODY STYLE | STRAIGHT SHAPE,EXTERNAL COUPLING |
ABKW | OVERALL HEIGHT | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND VIBRATION RESISTANT AND SALT WATER RESISTANT |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.557 INCHES MINIMUM AND 1.567 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.557 INCHES MINIMUM AND 1.567 INCHES MAXIMUM |
AFQZ | CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 22.0 SINGLE MATING END 1ST CONTACT GROUPING |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 41.0 SINGLE MATING END 2ND CONTACT GROUPING |
AFRT | SHELL TYPE | SOLID |
AFRV | CONNECTOR LOCKING METHOD | INTERNALLY THREADED COUPLING RING |
AFRW | CONNECTOR CABLE STRAIN RELIEF METHOD | CABLE CLAMP |
AKMG | NOMINAL THREAD LENGTH | 0.625 INCHES |
CQJX | NOMINAL THREAD SIZE | 1.750 INCHES |
CXCG | INCLUDED CONTACT QUANTITY | 10 SINGLE MATING END 2ND CONTACT GROUPING |
CXCG | INCLUDED CONTACT QUANTITY | 4 SINGLE MATING END 1ST CONTACT GROUPING |
THSD | THREAD SERIES DESIGNATOR | UNS |