Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-386-8158 (003868158) |
NCB Code | USA (00) |
Manufacturer | Allied Controls Inc, Military Specifications, Microsemi Corporation, Tyco Electronics Corporation, Electronic Specialty Corp, Leach International Corporation, Dri Relays Inc, Cp Clare Corp, Genicom Corp, Hi G Co Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
S6A1M26-5 | allied controls inc | relay electromagnetic | RFQ |
M5757-9-061 | military specifications | relay electromagnetic | RFQ |
BR26S350 | microsemi corporation | relay electromagnetic | RFQ |
HC11HP26-5V | tyco electronics corporation | relay electromagnetic | RFQ |
50GB0N1A700-6 | electronic specialty corp | relay electromagnetic | RFQ |
EA1A164 | leach international corporation | relay electromagnetic | RFQ |
HFW1201K22 | tyco electronics corporation | relay electromagnetic | RFQ |
DJ26C1P6A95 | dri relays inc | relay electromagnetic | RFQ |
HFW1201K22 | cp clare corp | relay electromagnetic | RFQ |
93220301-10 | dri relays inc | relay electromagnetic | RFQ |
3SAV1661A2 | genicom corp | relay electromagnetic | RFQ |
MILR5757-9 | military specifications | relay electromagnetic | RFQ |
2K2299-61 | hi g co inc | relay electromagnetic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.180 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.612 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 900.0 OHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-5757/9 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5945-00-386-8158, 5945003868158 | ||||
5975-00-900-5000 (5975009005000) | 5915-00-509-2939 (5915005092939) | 5995-01-622-9763 (5995016229763) | 5930-00-188-2156 (5930001882156) | |
5998-01-494-7223 (5998014947223) | 5905-01-529-9031 (5905015299031) | 5950-00-519-4719 (5950005194719) | 5998-01-070-9399 (5998010709399) | |
5935-01-007-6384 (5935010076384) | 5940-01-609-5218 (5940016095218) | 5998-00-781-1392 (5998007811392) | 5925-01-340-5534 (5925013405534) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote