MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 6.230 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 62.565 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 5.00 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 50.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 11 SCREW ALL FUNCTIONS |