Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-808-6345 (008086345) |
NCB Code | USA (00) |
Manufacturer | Military Specifications, Pall Gmbh, Edo Corporation, Ministry Of Defence Future, Northrop Grumman Systems Corporation, Leach International Europe Sas, Thales Nederland Bv, Struthers Dunn Inc, Lockheed Martin Corporation, Military Standards Corp, Lexan Industries Inc, Harris Corporation, Leach International Corporation, Raytheon Company, Sypris Electronics Llc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
M5757/18-005 | military specifications | relay electromagnetic | RFQ |
MCS1001EC | pall gmbh | relay electromagnetic | RFQ |
395577-1 | edo corporation | relay electromagnetic | RFQ |
40070272 | ministry of defence future | relay electromagnetic | RFQ |
M25271-A1 | military specifications | relay electromagnetic | RFQ |
MILR5757-18 | military specifications | relay electromagnetic | RFQ |
946598-1 | northrop grumman systems corporation | relay electromagnetic | RFQ |
9224-4076 | leach international europe sas | relay electromagnetic | RFQ |
352250029372 | thales nederland bv | relay electromagnetic | RFQ |
FC400-2 | struthers dunn inc | relay electromagnetic | RFQ |
348831 | lockheed martin corporation | relay electromagnetic | RFQ |
MS25271-A1 | military standards corp | relay electromagnetic | RFQ |
908951-00 | lockheed martin corporation | relay electromagnetic | RFQ |
FC400-62 | lexan industries inc | relay electromagnetic | RFQ |
MIL-PRF-6106 | military specifications | relay electromagnetic | RFQ |
G370033S1 | harris corporation | relay electromagnetic | RFQ |
MIL-R-6106 | military specifications | relay electromagnetic | RFQ |
5757 18-005 | edo corporation | relay electromagnetic | RFQ |
FC400-130 | struthers dunn inc | relay electromagnetic | RFQ |
9224-5779 | leach international corporation | relay electromagnetic | RFQ |
4170600-030 | raytheon company | relay electromagnetic | RFQ |
16600369-002 | sypris electronics llc | relay electromagnetic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.531 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
CBME | CUBIC MEASURE | 5.271 CUBIC INCHES |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS25271 GOVERNMENT STANDARD |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.531 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.249 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 400.0 NOMINAL |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC INDUCTIVE LOAD AND 6.0 AMPERES DC INDUCTIVE LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
Relevant Components for NSN - 5945-00-808-6345, 5945008086345 | ||||
5975-00-900-5000 (5975009005000) | 5915-00-509-2939 (5915005092939) | 5995-01-622-9763 (5995016229763) | 5930-00-188-2156 (5930001882156) | |
5998-01-494-7223 (5998014947223) | 5905-01-529-9031 (5905015299031) | 5950-00-519-4719 (5950005194719) | 5998-01-070-9399 (5998010709399) | |
5935-01-007-6384 (5935010076384) | 5940-01-609-5218 (5940016095218) | 5998-00-781-1392 (5998007811392) | 5925-01-340-5534 (5925013405534) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote