Database of Relay Electromagnetic Under NSN (5945012511350) 5945-01-251-1350 Parts

Item Name Relay Electromagnetic
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5945 Relays and Solenoids
National Item Identification Number (NIIN) 01-251-1350 (012511350)
NCB Code USA (01)
Manufacturer Tyco Electronics Agastat Relays, L 3 Communications Westwood
Part Number Manufacturer Item Name RFQ
7022MEN tyco electronics agastat relays relay electromagnetic RFQ
2422MEN tyco electronics agastat relays relay electromagnetic RFQ
7000P04002-1 l 3 communications westwood relay electromagnetic RFQ

Technical Characteristics of NSN 5945012511350

MRCCriteriaCharacteristic
AAJDTHREAD CLASS2B SECOND MOUNTING FACILITY
AAJFTHREAD DIRECTIONRIGHT-HAND SECOND MOUNTING FACILITY
ABHPOVERALL LENGTH3.250 INCHES MAXIMUM
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.880 INCHES NOMINAL FIRST MOUNTING FACILITY
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.750 INCHES NOMINAL SECOND MOUNTING FACILITY
ABKWOVERALL HEIGHT4.520 INCHES MAXIMUM
ABMKOVERALL WIDTH3.090 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
ADZCENVIRONMENTAL PROTECTIONDUSTPROOF
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.199 INCHES NOMINAL FIRST MOUNTING FACILITY
AEBWCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT0.500 INCHES NOMINAL SECOND MOUNTING FACILITY
AEBWCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY
AFJNFRAGILITY FACTORMODERATELY RUGGED
AKDXWINDING QUANTITY1
AKSLPURPOSE FOR WHICH DESIGNEDGENERAL
APCNCOIL QUANTITY1
APNPDUTY TYPECONTINUOUS
APNQARC QUENCHING METHODAIR
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE SECOND MOUNTING FACILITY
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE FIRST MOUNTING FACILITY
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CBMECUBIC MEASURE45.392 CUBIC INCHES
CMLPTHREAD QUANTITY PER INCH32 SECOND MOUNTING FACILITY
CQJXNOMINAL THREAD SIZE0.164 INCHES SECOND MOUNTING FACILITY
CQYJMOUNTING FACILITY PATTERNRECTANGULAR FIRST MOUNTING FACILITY
CQYJMOUNTING FACILITY PATTERNRECTANGULAR SECOND MOUNTING FACILITY
CRNGNONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY
CRXHTIME DELAY20.00 SECONDS MINIMUM FIXED RELEASE TIME AND 200.00 SECONDS MAXIMUM FIXED RELEASE TIME
CSXFOPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD
CWABMAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS240.0 AC AND 30.0 DC
CWJBENERGIZING ELEMENT POWER RATING8.0 WATTS
THSDTHREAD SERIES DESIGNATORUNC SECOND MOUNTING FACILITY
TTQYTERMINAL TYPE AND QUANTITY8 SCREW ALL FUNCTIONS

Relevant Components for NSN - 5945-01-251-1350, 5945012511350
5999-01-196-8879 (5999011968879) 5970-00-488-9670 (5970004889670) 5945-01-477-0491 (5945014770491) 5999-01-364-2930 (5999013642930)
5996-01-452-4386 (5996014524386) 5945-00-260-1626 (5945002601626) 5998-01-130-0814 (5998011300814) 5905-00-557-4486 (5905005574486)
5935-01-689-9407 (5935016899407) 5980-01-504-2998 (5980015042998) 5935-00-644-6464 (5935006446464) 5995-01-277-3853 (5995012773853)