Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-255-3896 (012553896) |
NCB Code | USA (01) |
Manufacturer | Tyco Electronics Corporation, Textron Systems Corporation, San Antonio Air Logistics Center |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
KUP-5D15-12 | tyco electronics corporation | relay electromagnetic | RFQ |
5945-034-0002 | textron systems corporation | relay electromagnetic | RFQ |
X916741 | san antonio air logistics center | relay electromagnetic | RFQ |
X916741-1 | san antonio air logistics center | relay electromagnetic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.531 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 2.197 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.406 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AFRG | CONTACT MATERIAL | SILVER |
AGAV | END ITEM IDENTIFICATION | RS TEST SYSTEM |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 120.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 4.729 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES DC SINGLE WINDING |
CRXH | TIME DELAY | 0.01 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 28.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 1.2 WATTS |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 5 QUICK DISCONNECT,MALE ALL FUNCTIONS |
Relevant Components for NSN - 5945-01-255-3896, 5945012553896 | ||||
5930-01-024-7616 (5930010247616) | 5935-01-207-1630 (5935012071630) | 5930-00-522-3346 (5930005223346) | 5985-01-615-6045 (5985016156045) | |
5910-00-805-1017 (5910008051017) | 5962-01-297-8133 (5962012978133) | 5935-01-108-9409 (5935011089409) | 5910-01-082-8261 (5910010828261) | |
5930-01-681-7491 (5930016817491) | 5930-01-322-8532 (5930013228532) | 5935-00-755-3452 (5935007553452) | 5985-01-676-2667 (5985016762667) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote