Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-241-0114 (002410114) |
NCB Code | USA (00) |
Manufacturer | Jeans Extrusions, Ail Systems Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
16374 | jeans extrusions | transformer power | RFQ |
73P818-001 | ail systems inc | transformer power | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.490 INCHES MINIMUM AND 3.510 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.740 INCHES MINIMUM AND 3.760 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 75.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 0.65 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.5 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY9.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY29.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY29.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY100.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 29.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY9.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | 3 PRIMARY WINDINGS; 8 SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 35 TURRET |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
Relevant Components for NSN - 5950-00-241-0114, 5950002410114 | ||||
5975-00-900-5000 (5975009005000) | 5915-00-509-2939 (5915005092939) | 5995-01-622-9763 (5995016229763) | 5930-00-188-2156 (5930001882156) | |
5998-01-494-7223 (5998014947223) | 5905-01-529-9031 (5905015299031) | 5950-00-519-4719 (5950005194719) | 5998-01-070-9399 (5998010709399) | |
5935-01-007-6384 (5935010076384) | 5940-01-609-5218 (5940016095218) | 5998-00-781-1392 (5998007811392) | 5925-01-340-5534 (5925013405534) | |