Database of Transformer Power Under NSN (5950003858906) 5950-00-385-8906 Parts

Item Name Transformer Power
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5950 Coils and Transformers
National Item Identification Number (NIIN) 00-385-8906 (003858906)
NCB Code USA (00)
Manufacturer Berkshire Transformer, Coil Specialty Co Inc, Transformer Engineering Llc, Astec America Inc, Saga Engineering Corp, Data Products Corp, Baltimore Transformer Company, Freed Transformer Company
Part Number Manufacturer Item Name RFQ
BC6666 berkshire transformer transformer power RFQ
CS6423 coil specialty co inc transformer power RFQ
213955-1 transformer engineering llc transformer power RFQ
213955-1 astec america inc transformer power RFQ
213955-1 saga engineering corp transformer power RFQ
213955-1 data products corp transformer power RFQ
BX-9365 baltimore transformer company transformer power RFQ
43690 freed transformer company transformer power RFQ
49336 astec america inc transformer power RFQ

Technical Characteristics of NSN 5950003858906

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
ACZBFREQUENCY RATING47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ACZXWINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ADAQBODY LENGTH5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM
ADATBODY WIDTH4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM
ADAUBODY HEIGHT4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM
AKNAINCLOSURE TYPEFULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY8 ALL GROUPINGS8 ALL GROUPINGS8 ALL GROUPINGS
AXGYMOUNTING METHODTHREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGS
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT
CQJXNOMINAL THREAD SIZE0.250 INCHES ALL GROUPINGS0.250 INCHES ALL GROUPINGS
CRBZWINDING OPERATING CURRENT0.6 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT3.0 AMPERES DC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 8.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT4.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
CWJSWINDING OPERATING VOLTAGE15.00 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 30.00 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE9.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
FEATSPECIAL FEATURESALL VOLTAGES ARE STATED AS OPEN CIRCUIT; ALL CURRENTS ARE STATED AS RECTIFIED; 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARIES 5 & 6 ARE RATED 115VRMS
THSDTHREAD SERIES DESIGNATORUNF ALL GROUPINGS
TTQYTERMINAL TYPE AND QUANTITY20 THREADED STUD

Relevant Components for NSN - 5950-00-385-8906, 5950003858906
5999-01-196-8879 (5999011968879) 5970-00-488-9670 (5970004889670) 5945-01-477-0491 (5945014770491) 5999-01-364-2930 (5999013642930)
5996-01-452-4386 (5996014524386) 5945-00-260-1626 (5945002601626) 5998-01-130-0814 (5998011300814) 5905-00-557-4486 (5905005574486)
5935-01-689-9407 (5935016899407) 5980-01-504-2998 (5980015042998) 5935-00-644-6464 (5935006446464) 5995-01-277-3853 (5995012773853)