Buy Military Ground Vehicle Parts is a one-stop shop for NSN 5950-00-617-4251 supplies, our selection currently featuring popular part numbers like TF4RX03MB004, MIL-PRF-27, MS90030-2, MIL-T-27, and others. With everything featured on our catalog being available for purchase today, do not hesitate to begin exploring options while utilizing provided listing resources to narrow your search. Alongside simplifying the process of locating NSN 5950-00-617-4251 parts of interest, we have also streamlined the quotation process with our online Request for Quote (RFQ) forms. By filling out and submitting a request on our website with information on your needs, our staff will be able to provide you with fully customized purchasing options for your consideration.
We aim to provide the most reliable procurement options for our customers, following a strict sourcing policy that ensures that all NSN 5950-00-617-4251 parts we stock can be traced back to a trusted manufacturer. Furthermore, customers can rest easy knowing that our staff will work closely with them to find options that meet any time constraints or purchasing options, with consultation offered for any expedited delivery requests. With all of this in mind, be sure to get in contact with us at any time if you have any inquiries or purchasing requests!
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-617-4251 (006174251) |
NCB Code | USA (00) |
Manufacturer | Military Specifications, Military Standards Corp |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
TF4RX03MB004 | military specifications | transformer power | RFQ |
MIL-PRF-27 | military specifications | transformer power | RFQ |
MS90030-2 | military standards corp | transformer power | RFQ |
MIL-T-27 | military specifications | transformer power | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.688 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.938 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | SPRUANCE CLASS DD (963); LANDING CRAFT AIR CUSHION (LCAC); VIRGINIA CLASS CGN (41); FORRESTAL CLASS CV; TICONDEROGA CLASS CG (47); LOS ANGELES CLASS SSN (688); STURGEON CLASS SSN (637); KIDD CLASS DDG; NIMITZ CLASS CVN |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.91 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 250.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 8.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 900.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB,SOLDER LUG |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS90030 GOVERNMENT STANDARD |
Relevant Components for NSN - 5950-00-617-4251, 5950006174251 | ||||
5935-01-207-0003 (5935012070003) | 5950-00-480-9651 (5950004809651) | 5935-01-613-5741 (5935016135741) | 5915-01-631-4880 (5915016314880) | |
5998-00-483-1527 (5998004831527) | 5985-01-305-0867 (5985013050867) | 5905-00-461-3117 (5905004613117) | 5940-01-452-4369 (5940014524369) | |
5920-00-875-3856 (5920008753856) | 5961-01-426-3250 (5961014263250) | 5905-00-056-5759 (5905000565759) | 5905-00-480-6880 (5905004806880) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote