Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-208-4783 (012084783) |
NCB Code | USA (01) |
Manufacturer | Hamilton Sundstrand Corporation, Dla Land And Maritime |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.080 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.480 INCHES MINIMUM AND 1.560 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 12.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 48.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
CRMJ | WINDING POWER RATING | 5.16 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 5.52 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 353.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 430.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | NUCLEAR HARDNESS CRITICAL ITEM |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LOOP |
Relevant Components for NSN - 5950-01-208-4783, 5950012084783 | ||||
5985-01-360-2114 (5985013602114) | 5950-01-481-1072 (5950014811072) | 5910-01-015-2302 (5910010152302) | 5930-00-578-6955 (5930005786955) | |
5975-01-563-7366 (5975015637366) | 5950-01-261-6319 (5950012616319) | 5962-01-133-3642 (5962011333642) | 5915-01-464-8685 (5915014648685) | |
5935-00-763-8252 (5935007638252) | 5910-00-833-8207 (5910008338207) | 5905-01-258-4942 (5905012584942) | 5935-00-825-5145 (5935008255145) | |