MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM FIRST FLANGE AND 0.904 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.406 INCHES MINIMUM FIRST FLANGE AND 1.437 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
CMLP | THREAD QUANTITY PER INCH | 32 FIRST FLANGE ALL CONNECTION FACILITIES |
CQGM | MAXIMUM OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | DOUBLE BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
AHSY | FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM FIRST FLANGE AND 0.404 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CXBD | WAVEGUIDE HEIGHT | 1.495 INCHES MINIMUM AND 1.505 INCHES MAXIMUM |