MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AGAV | END ITEM IDENTIFICATION | OA-9233 A/G, OPERATIONS GROUP VAN |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 1.122 INCHES NOMINAL FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.372 INCHES NOMINAL SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.497 INCHES NOMINAL FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.622 INCHES NOMINAL SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 2.500 INCHES NOMINAL FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 2.690 INCHES NOMINAL SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.750 INCHES NOMINAL FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.940 INCHES NOMINAL SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.500 INCHES NOMINAL FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.500 INCHES NOMINAL SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL FIRST FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.196 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
BBPN | ADAPTER LENGTH | 6.000 INCHES NOMINAL |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.258 INCHES NOMINAL AND 1.508 INCHES NOMINAL |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.122 INCHES NOMINAL AND 1.372 INCHES NOMINAL |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.497 INCHES NOMINAL AND 0.622 INCHES NOMINAL |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.633 INCHES NOMINAL AND 0.758 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CONTACT TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | CONTACT TYPE SECOND FLANGE |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | WAVEGUIDE TRANSITION, WR112-WR137 |
FEAT | SPECIAL FEATURES | BRASS FLANGES ARE PRESSURIZABLE CPR CONTACT TYPE M3922/52-041 (WR112) & M3922/52-039, CLEAR MTG HOLES IAW MIL-DTL-3922/52; TEMP RANGE: -35 TO +66 DEG C |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AGAV | END ITEM IDENTIFICATION | OA-9233 A/G, OPERATIONS GROUP VAN |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 1.122 INCHES NOMINAL FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.372 INCHES NOMINAL SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.497 INCHES NOMINAL FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.622 INCHES NOMINAL SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 2.500 INCHES NOMINAL FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 2.690 INCHES NOMINAL SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.750 INCHES NOMINAL FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.940 INCHES NOMINAL SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.500 INCHES NOMINAL FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.500 INCHES NOMINAL SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL FIRST FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.196 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
BBPN | ADAPTER LENGTH | 6.000 INCHES NOMINAL |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.258 INCHES NOMINAL AND 1.508 INCHES NOMINAL |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.122 INCHES NOMINAL AND 1.372 INCHES NOMINAL |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.497 INCHES NOMINAL AND 0.622 INCHES NOMINAL |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.633 INCHES NOMINAL AND 0.758 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CONTACT TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | CONTACT TYPE SECOND FLANGE |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | WAVEGUIDE TRANSITION, WR112-WR137 |
FEAT | SPECIAL FEATURES | BRASS FLANGES ARE PRESSURIZABLE CPR CONTACT TYPE M3922/52-041 (WR112) & M3922/52-039, CLEAR MTG HOLES IAW MIL-DTL-3922/52; TEMP RANGE: -35 TO +66 DEG C |
MATT | MATERIAL | COPPER SINGLE TUBING SEGMENT |
STYL | III STYLE DESIGNATOR | WAVEGUIDE TO WAVEGUIDE |
MATT | MATERIAL | COPPER SINGLE TUBING SEGMENT |
STYL | III STYLE DESIGNATOR | WAVEGUIDE TO WAVEGUIDE |