MRC | Criteria | Characteristic |
---|
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | W/O AMPLIFIER |
RDAL | III REFERENCE DATA AND LITERATURE | COMMERCIAL HANDBOOK AND TO 33A1-13-73-1 |
FEAT | SPECIAL FEATURES | VERTICAL PLUG-IN UNITS,FOR MULTIPLE-TRACE OPERATION- TYPE 1A1 DUAL-TRACE UNIT- DC TO 33 MC,10.5-NANOSECOND RISETIME AT 50 MV/CM-DC TO 23 MC,15-NANOSECOND RISETIME AT 5 MV/CM INCREASING TO 33 MC AT 50 MV/CM; TYPE 1A2 DUAL-TRACE UNIT-DC TO 33 MC,10.5-NANOSECOND RISETIME AT 50 MV/CM TO 50 V/CM; TYPE C-A DUAL-TRACE UNIT-DC TO 24 MC,15 NANOSECOND RISETIME AT 50 MV/CM TO 25 V/CM; TYPE M FOUR-TRACE UNIT-DC TO 20 MC,17-NANOSECOND RISETIME AT 20 MV/CM TO 25 V/CM |
BGQM | GENERATOR DRIVEN FEATURE | NOT INCLUDED |
BHFF | CALIBRATED SCREEN SCALE | NOT INCLUDED |
BHFH | TRACE STORAGE TUBE | NOT INCLUDED |
SR-5 | THE MANUFACTURERS DATA | |
BHDL | PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION | PROVIDED |
SR-5 | MANUFACTURERS CODE | 80009 |
BHDN | DIRECT CONNECTION HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING | 30.0 VOLTS NOMINAL PEAK TO PEAK PER CENTIMETER |
BGQL | SWEEP CIRCUITS | NOT INCLUDED |
BHDR | Y-AXIS FREQUENCY RESPONSE RATING | 5.0 HERTZ MINIMUM AND 30000000.0 HERTZ MAXIMUM |
BHDT | AMPLIFIER INPUT IMPEDANCE RATING PROVISION | PROVIDED |
BHDX | Y-AXIS INPUT IMPEDANCE RATING | 1.0 MEGOHMS NOMINAL |
BHDY | Z-AXIS INPUT IMPEDANCE RATING | 1.0 MEGOHMS NOMINAL |
BHFT | CAMERA RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
BHDG | HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING | 200.0 MILLIVOLTS NOMINAL PEAK TO PEAK PER CENTIMETER |
NTRD | III ENTRY DATE | 70-04-01 |
BGSD | EXPANDED SWEEP | NOT PROVIDED |
FAAZ | PHASE | SINGLE |
ATES | BEAM QUANTITY | 1 |
BHDD | AMPLIFIER DEFLECTION SENSITIVITY PROVISION | PROVIDED |
BHDH | INPUT INTENSITY MODULATION FEATURE | NOT PROVIDED |
BHDP | FREQUENCY RESPONSE RATING | PROVIDED |
AMSE | VOLTAGE RATING | 125.0 VOLTS NOMINAL |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | 2 ADAPTER,POST,1 CORD,POWER,1 FILTER,LIGHT,1 LEAD,TEST,1 MANUAL,INSTRUCTION,2 PROBES,10 X ATTENUATION |
SR-5 | DESIGN CONTROL REFERENCE | 545 |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
ABMK | OVERALL WIDTH | 13.000 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 24.000 INCHES NOMINAL |
FCLS | III FUNCTIONAL CLASSIFICATION | AA-3.2 |
FTLD | III FUNCTIONAL DESCRIPTION | HIGH-SPEED LABORATORY OSCILLOSCOPE W/FAST RISE TIME COUPLED WITH WIDE SWEEP-SPEED RANGE AND 10KILOVOLT ACCELERATING VOLTAGE OPENS THE WAY TO FASTER,EASIER ANALYSIS OF FAST-RISING WAVEFORMS. ADDITIONAL ADAPTABILITY IS PROVIDED BY PLUG-IN PREAMPLIFIERS WHICH EXTENDS ITS USE TO ALMOST ALL LABORATORY-OSCILLOSCOPE APPLICATIONS. ACCURATELY CALIBRATED SWEEP SPEEDS AND VERTICAL-DEFLECTION SENSITIVITY PERMIT QUANTITATIVE TIME AND AMPLITUDE MEASUREMENTS TO BE MADE. ACCURATELY-DELAYED TRIGGERED SWEEPS MAKE POSSIBLE THE SELECTION AND DETAILED OBSERVATION OF MINUTE PORTIONS OF VOLTAGE WAVES |
BHDF | VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING | 50.0 MICROVOLTS NOMINAL PEAK TO PEAK PER CENTIMETER |
BGQK | SCREEN SIZE | 5 IN. |
ABKW | OVERALL HEIGHT | 16.000 INCHES NOMINAL |
BHDM | DIRECT CONNECTION VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING | 7.0 VOLTS NOMINAL PEAK TO PEAK PER CENTIMETER |
BHDW | X-AXIS INPUT IMPEDANCE RATING | 1.0 MEGOHMS NOMINAL |
BHDQ | X-AXIS FREQUENCY RESPONSE RATING | 5.0 HERTZ MINIMUM AND 240000.0 HERTZ MAXIMUM |
ACDC | CURRENT TYPE | AC |
RTSE | III RELATIONSHIP TO SIMILAR EQUIPMENT | INTERCHANGEABLE WITH NSN 6625-00-909-7025 |