Thank you for taking an interest in the Insulation Sleeving Electrical S NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 573H157-6, an item that traces back to the manufacturer 3M Co Admininistrative Electronic. Listed with NSN 5970012919363, this listing is available for purchase from our website at any time. If you are interested in part number 573H157-6 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5970-01-291-9363 Item PartTypeName: INSULATION SLEEVING,ELECTRICAL,S | 5970 | 012919363 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
573H157-6 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABJH | TEMP RATING | -55.0 DEG CELSIUS |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
AFZU | MAIN BODY INSIDE DIAMETER | 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZU | MAIN BODY INSIDE DIAMETER | 2.190 INCHES MINIMUM AS SUPPLIED |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZW | SECOND BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | THIRD BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAB | MAIN BODY WALL THICKNESS | 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAC | FIRST BRANCH WALL THICKNESS | 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAD | SECOND BRANCH WALL THICKNESS | 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAE | THIRD BRANCH WALL THICKNESS | 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAH | MAIN BODY OVERALL LENGTH | 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
CQBC | MINIMUM TENSILE STRENGTH | 1200 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
HUES | COLOR | BLACK |
MATT | MATERIAL | PLASTIC,POLYOLEFIN,RT-1304,RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPF-666,3M CO |
STYL | STYLE DESIGNATOR | TRANSITION-1 TO 3 CABLES |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 225.0 VOLTS PER MIL /0.001 INCH |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote