Thank you for taking an interest in the Circuit Breaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number APL-1-1-51-303-H, an item that traces back to the manufacturer Airpax Corp. Listed with NSN 5925016262112, this listing is available for purchase from our website at any time. If you are interested in part number APL-1-1-51-303-H and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-626-2112 Item PartTypeName: CIRCUIT BREAKER | 5925 | 016262112 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
APL-1-1-51-303-H | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 1 |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.060 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 2.495 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERVOLTAGE ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
ADAT | Body Width | 0.755 INCHES NOMINAL |
CXCY | Part Name Assigned By Controlling Agency | HYDRAULIC MAGNETIC CIRCUIT PROTECTOR |
CPRQ | Reset Method | MANUAL |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
AGAV | End Item Identification | CONTROL,RECEIVER-TRANSMITTER NSN 5895-33-201-6127 |
ADAQ | Body Length | 2.530 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.0 MINIMUM AT 125 PCT AND 18.0 MAXIMUM AT 125 PCT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.