Thank you for taking an interest in the Circuit Breaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 10047, an item that traces back to the manufacturer Ap Labs Inc. Listed with NSN 5925014859638, this listing is available for purchase from our website at any time. If you are interested in part number 10047 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-485-9638 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014859638 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M39019/03-055S | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 1.828 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
AAQL | Body Style | |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
CPRH | Circuit Protection Type | REVERSE PHASE ALL LOCATIONS |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-39019/3 GOVERNMENT SPECIFICATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 4 SCREW |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF AND FUNGUS PROOF AND HERMETICALLY SEALED AND MOISTURE PROOF |
MRC | Decoded Requirement | Clear Text Reply |
TEST | Test Data Document | 81349-MIL-PRF-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote