Thank you for taking an interest in the Powersupply NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number SYS-3081, an item that traces back to the manufacturer Atc Power Systems Inc. Listed with NSN 6130013465836, this listing is available for purchase from our website at any time. If you are interested in part number SYS-3081 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-346-5836 Item PartTypeName: POWER SUPPLY | 6130 | 013465836 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SYS-3081 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 7.250 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | AN/USM-638; USED ON 8949102 |
APTQ | INPUT FREQUENCY RATING | 380.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT57.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT47.5 HERTZ MINIM |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE SINGLE POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
CWWY | POWER SUPPLY EFFICIENCY LINE | 70.0 |
ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 207.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 253.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT103.5 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 126.5 AC POUNDS PER HOUR |
APPA | OUTPUT VOLTAGE RATING | 26.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 30.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT14.65 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 15.55 DC VOLTS MAXIMUM 2ND POWER OUTPUT14.65 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 15.55 DC VOLTS MAXIMUM 3RD POWER |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | CONNECTOR,PLUG SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -40.0/71.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT4.0 DC AMPERES NOMINAL 2ND POWER OUTPUT2.5 DC AMPERES NOMINAL 3RD POWER OUTPUT5.0 DC AMPERES NOMINAL 4TH POWER OUTPUT16.0 DC AMPERES NOMINAL 5TH POWER OUTPUT-2.0 DC AMPERES NOMINAL 6TH POWER OUTPUT |
CWKG | VENTILATION DESIGN TYPE | SINGLE FAN |
FEAT | SPECIAL FEATURES | ELECTROSTATIC SENSITIVE DEVICE |