Thank you for taking an interest in the Relay Electromagnetic NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 3SAE5081N1, an item that traces back to the manufacturer Communications Instruments Inc. Listed with NSN 5945008109112, this listing is available for purchase from our website at any time. If you are interested in part number 3SAE5081N1 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-810-9112 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 008109112 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3S2791G200R11 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.488 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.790 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 1.278 KILOHMS NOMINAL SINGLE WINDING |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 0.870 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.350 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 38.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.