Thank you for taking an interest in the Circuit Breaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number AM3 C2C3C3 25 2, an item that traces back to the manufacturer Eaton Corporation. Listed with NSN 5925010487916, this listing is available for purchase from our website at any time. If you are interested in part number AM3 C2C3C3 25 2 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.800 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES AC ALL LOCATIONS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 5.0 DC |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 30.0 DC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |