Thank you for taking an interest in the Switch Radio Frequency Transmiss NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number CS12228, an item that traces back to the manufacturer Emberguard Solutions. Listed with NSN 5985010694202, this listing is available for purchase from our website at any time. If you are interested in part number CS12228 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-069-4202 Item PartTypeName: SWITCH,RADIO FREQUENCY TRANSMISS | 5985 | 010694202 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2412-4005-00 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.440 INCHES NOMINAL |
AEEA | SWITCH TYPE | NONTRANSFER |
AFGA | OPERATING TEMP RANGE | -54.0 TO 115.0 DEG CELSIUS |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.60 1ST |
AHTW | VOLTAGE STANDING WAVE RATIO | 2.00 2ND |
AHTW | VOLTAGE STANDING WAVE RATIO | 2.50 3RD |
AHTX | INSERTION LOSS IN DECIBELS | 0.75 1ST |
AHTX | INSERTION LOSS IN DECIBELS | 1.10 2ND |
AHTX | INSERTION LOSS IN DECIBELS | 1.50 3RD |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | SMA |
AHUD | CONNECTOR END DESIGN | FEMALE AND MALE |
AKNV | MINIMUM CROSSTALK RATING IN DECIBELS | 20.0 SINGLE |
AKPP | SWITCHING TIME | 10.0 MILLISECONDS |
AKPQ | SWITCH RETURN MECHANISM TYPE | FAIL-SAFE |
AKPX | POLE QUANTITY | 1 |
AKPY | THROW QUANTITY | 2 |
AKRC | COUPLING POSITION QUANTITY | 3 |
FEAT | SPECIAL FEATURES | FUNGUS RESISTANT PER MIL-STD-454 REQ 4 |
MATT | MATERIAL | STEEL CORROSION RESISTING CONNECTOR(S) |
SFTT | SURFACE TREATMENT | PASSIVATE CONNECTOR(S) OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | TIN TERMINAL(S) OUTSIDE SURFACES |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-35 FED SPEC SINGLE TREATMENT RESPONSE CONNECTOR(S) OUTSIDE SURFACES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 RECEPTACLE,COAXIAL AND 1 PLUG,COAXIAL |