Thank you for taking an interest in the Circuit Breaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 62135-2, an item that traces back to the manufacturer Engineered Air Systems Inc. Listed with NSN 5925014726701, this listing is available for purchase from our website at any time. If you are interested in part number 62135-2 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-472-6701 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014726701 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
62135-2 | 5 | 9 | D |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 1 CLIP |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 2.250 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 4.134 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
ADAU | Body Height | 2.874 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 3 CLIP |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.