Thank you for taking an interest in the Transformer Power NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 272.404 431, an item that traces back to the manufacturer Esw Gmbh. Listed with NSN 5950013800936, this listing is available for purchase from our website at any time. If you are interested in part number 272.404 431 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-380-0936 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013800936 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DGM/M-10200VA-50HZ-40071034462 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 1ST GROUP |
CWJS | WINDING OPERATING VOLTAGE | 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 130.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 2ND CENTER GROUP |
ABKW | OVERALL HEIGHT | 267.0 MILLIMETERS NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 11.0 MILLIMETERS NOMINAL 2ND GROUP |
ABHP | OVERALL LENGTH | 410.0 MILLIMETERS NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 165.0 MILLIMETERS MAXIMUM ALL MOUNTING FACILITIES 1ST CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 57.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 2ND CENTER GROUP |
ABMK | OVERALL WIDTH | 173.0 MILLIMETERS NOMINAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 1ST GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 82.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 10.2 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | IN MRC CBBL RESISTORS ARE VARIABLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 260.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 1ST CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 16.0 MILLIMETERS NOMINAL 1ST GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 65.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 6 2ND GROUP |
AXGY | MOUNTING METHOD | SLOT 2ND GROUP |
CBBL | FEATURES PROVIDED | W/RESISTOR |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TERMINAL BLOCK W/SCREWS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote