Thank you for taking an interest in the Fuseholder Extractor Post NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number A A 55504 2, an item that traces back to the manufacturer Federal Commercial Item Description. Listed with NSN 5920013490012, this listing is available for purchase from our website at any time. If you are interested in part number A A 55504 2 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5920-01-349-0012 Item PartTypeName: FUSEHOLDER,EXTRACTOR POST | 5920 | 013490012 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AA55504/02-002B | 5 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.660 INCHES NOMINAL |
ABTJ | MOUNTING HOLE QUANTITY | 1 |
AFRH | CONTACT SURFACE TREATMENT | TIN PLATED |
AAFZ | BODY MATERIAL | PLASTIC,PHENOLIC,MOULDED |
ABDM | TERMINAL MATERIAL | COPPER ALLOY |
ABMK | OVERALL WIDTH | 0.920 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.502 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | VIBRATION PROOF |
AEVB | MOUNTING HOLE STYLE | BUSHING MOUNTING |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGUL | ACCOMMODATED FUSE WIDTH | 0.203 INCHES NOMINAL |
AGUU | BUSHING THREAD LENGTH | 0.500 INCHES NOMINAL |
AGVF | BUSHING HOLE DIAMETER | 0.502 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG |
AAQL | BODY STYLE | BUSHING MOUNTED TYPE |
AFRG | CONTACT MATERIAL | COPPER ALLOY |
AGUV | CAP DIAMETER | 0.650 INCHES NOMINAL |
AGVH | FLATTED SIDE BUSHING HOLE LENGTH | 0.475 INCHES MINIMUM AND 0.480 INCHES MAXIMUM |
CSNM | FUSE TERMINAL TYPE ACCOMMODATED | FERRULE |
ABDN | TERMINAL SURFACE TREATMENT | TIN PLATED |
ABKH | BUSHING DIAMETER | 0.500 INCHES NOMINAL |
AGUE | FUSE ACCOMMODATION QUANTITY | 1 |
AGUJ | ACCOMMODATED FUSE LENGTH | 0.796 INCHES NOMINAL |
AGUT | LENGTH FROM FRONT PROTRUSION TO MOUNTING SURFACE | 0.450 INCHES NOMINAL |
CQJL | CURRENT CARRYING RATING IN AMPS | 6.3 |
ELEC | VOLTAGE IN VOLTS | 250.0 |