Thank you for taking an interest in the Transformer Power Autotransforme NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number BA40, an item that traces back to the manufacturer Ferranti Electric Inc. Listed with NSN 5950008504724, this listing is available for purchase from our website at any time. If you are interested in part number BA40 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-850-4724 Item PartTypeName: TRANSFORMER,POWER AUTOTRANSFORME | 5950 | 008504724 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
66-300 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY,FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 3.6 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRBZ | WINDING OPERATING CURRENT | 820.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 3 TAB,SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.310 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.100 INCHES MINIMUM SINGLE GROUP AND 0.105 INCHES MAXIMUM SINGLE GROUP |
ADAT | BODY WIDTH | 1.062 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
CRMJ | WINDING POWER RATING | 72.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |