Thank you for taking an interest in the Transformer Power NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 2805507P1, an item that traces back to the manufacturer General Dynamics Defense Systems. Listed with NSN 5950010885409, this listing is available for purchase from our website at any time. If you are interested in part number 2805507P1 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-088-5409 Item PartTypeName: TRANSFORMER,POWER | 5950 | 010885409 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R102876 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 16.750 INCHES MINIMUM AND 17.000 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 15.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 12.700 INCHES MINIMUM AND 13.100 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 11.940 INCHES MINIMUM AND 12.060 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.765 INCHES MINIMUM SINGLE GROUP AND 0.790 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | CORE GROUNDED SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 195.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
FEAT | SPECIAL FEATURES | TWO,ONE IN. INSIDE DIAMETER REMOVABLE EYEBOLTS PROVIDED FOR LIFTING |
TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote