Thank you for taking an interest in the Power Supply NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 756762-1, an item that traces back to the manufacturer Hamilton Sundstrand Corporation. Listed with NSN 6130010142851, this listing is available for purchase from our website at any time. If you are interested in part number 756762-1 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-014-2851 Item PartTypeName: POWER SUPPLY | 6130 | 010142851 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
77C717497P003 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.312 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.125 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM 3RD OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 200.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 240.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 4.8 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 5.5 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 3RD OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE BRIDGE |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 2.8 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 7.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |