Thank you for taking an interest in the Transformerassembly NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 10064340-101, an item that traces back to the manufacturer Honeywell International Inc. Listed with NSN 5950011823759, this listing is available for purchase from our website at any time. If you are interested in part number 10064340-101 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-182-3759 Item PartTypeName: TRANSFORMER ASSEMBLY | 5950 | 011823759 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10064340-101 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 228 ALL COMPONENTS SINGLE SECONDARY |
ABHY | TURN QUANTITY | 690 1ST COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 690 2ND COMPONENT 1ST PRIMARY |
ABHY | TURN QUANTITY | 690 3RD COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 744 2ND COMPONENT 2ND PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | CORE GROUNDED AND BROUGHT OUT TO TERMINAL 2ND COMPONENT AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 1ST COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BKPL | RATING METHOD | WINDING TURNS SINGLE COMPONENT SINGLE WINDING |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 1 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 1 SECONDARY 3RD COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY 2ND COMPONENT AND 1 SECONDARY 2ND COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.00445 INCHES AMERICAN WIRE GAGE 2ND COMPONENT 2ND PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01264 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01264 INCHES AMERICAN WIRE GAGE 2ND COMPONENT 1ST PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01264 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 199.20 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 199.20 AC VOLTS NOMINAL 2ND COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 199.20 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 214.80 AC VOLTS NOMINAL 2ND COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 65.80 AC VOLTS NOMINAL ALL COMPONENTS SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.