Thank you for taking an interest in the Relay Electromagnetic NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number KDL-D2A-006, an item that traces back to the manufacturer Leach International Corporation. Listed with NSN 5945013328005, this listing is available for purchase from our website at any time. If you are interested in part number KDL-D2A-006 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-332-8005 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013328005 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
280-42018-101 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.615 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.635 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.655 INCHES MAXIMUM |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 75.0 MILLIAMPERES DC SINGLE WINDING |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE HOOK ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.025 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGAV | END ITEM IDENTIFICATION | WEAPONS DELIV |
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL SINGLE WINDING |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES AC INDUCTIVE LOAD AND 12.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 PROBE AC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 DUAL 16 STAGE AC LAMP LOAD |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 PROBE AC RESISTIVE LOAD |
CBME | CUBIC MEASURE | 2.914 CUBIC INCHES |
CRXH | TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |