Thank you for taking an interest in the Waveguide Assembly NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number R50-121-1, an item that traces back to the manufacturer Microwave Engineering Corporation. Listed with NSN 5985013423413, this listing is available for purchase from our website at any time. If you are interested in part number R50-121-1 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-342-3413 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 013423413 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3452591-1 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B FIRST FLANGE SECOND CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SECOND CONNECTION FACILITY |
AHSY | FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM FIRST FLANGE AND 0.324 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM FIRST FLANGE AND 0.265 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
CMLP | THREAD QUANTITY PER INCH | 32 FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR DOUBLE RIDGED EXTERNAL,RECTANGULAR DOUBLE INDENTED |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM FIRST FLANGE AND 0.694 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.145 INCHES MINIMUM FIRST FLANGE FIRST CONNECTION FACILITY AND 0.148 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AHTX | INSERTION LOSS IN DECIBELS | 0.15 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 THREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CONTACT,DOUBLE RIDGE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTFD | WAVEGUIDE LENGTH | 3.365 INCHES MINIMUM AND 3.385 INCHES MAXIMUM |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SECOND CONNECTION FACILITY |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.788 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote