Thank you for taking an interest in the Switch Thermostatic NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number M24236/20-LCHB, an item that traces back to the manufacturer Military Specifications. Listed with NSN 5930011359723, this listing is available for purchase from our website at any time. If you are interested in part number M24236/20-LCHB and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-135-9723 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 011359723 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MIL-PRF-24236/20 | 5 | 1 | 4 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.836 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.360 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.720 NOMINAL CENTIMETERS |
ABTD | MOUNTING SLOT WIDTH | 0.104 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES MINIMUM AND 0.999 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | ON188GYK29000 |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AWTN | OPERATING TEMP RATING | -10.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | SLOT |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.5 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 50.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 43.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 48.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 2.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 5.00 DIFFERENTIAL POIN |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | DISC |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/20 GOVERNMENT SPECIFICATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote