Thank you for taking an interest in the Transformer Power NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number M27/349-04, an item that traces back to the manufacturer Military Specifications. Listed with NSN 5950013503702, this listing is available for purchase from our website at any time. If you are interested in part number M27/349-04 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-350-3702 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013503702 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MIL-PRF-27/349 | 5 | 1 | 4 |
MRC | Criteria | Characteristic |
---|---|---|
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.47 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 375.0 VOLT-AMPERE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.990 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.240 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.940 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 28.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TURRET |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-T-27/349 GOVERNMENT SPECIFICATION |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.450 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.58 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.