Thank you for taking an interest in the Transformer Power NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 1931-25 P N 25612, an item that traces back to the manufacturer Power Paragon Inc. Listed with NSN 5950013760922, this listing is available for purchase from our website at any time. If you are interested in part number 1931-25 P N 25612 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-376-0922 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013760922 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1931-25 P/N 25612 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 9.875 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 11.750 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 450.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
CRBZ | WINDING OPERATING CURRENT | 55.6 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 25.0 KILOVOLT-AMPERE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 86301-1931-25 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
ABKW | OVERALL HEIGHT | 16.750 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.406 INCHES NOMINAL SINGLE GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 50.0 DEG CELSIUS |
CRBZ | WINDING OPERATING CURRENT | 95.2 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 25.0 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 262.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.