Thank you for taking an interest in the Transformer Power NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number PEI 10093, an item that traces back to the manufacturer Precision Electronics Inc. Listed with NSN 5950000193007, this listing is available for purchase from our website at any time. If you are interested in part number PEI 10093 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-019-3007 Item PartTypeName: TRANSFORMER,POWER | 5950 | 000193007 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
256867 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 11.125 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.188 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 7.218 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.296 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.328 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 8.095 INCHES MINIMUM AND 8.155 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.25 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 12.0 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 9.60 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 25 TURRET |