Item Name : Circuit Breaker
CAGE Code: 49956
FSG: 59 Electrical and Electronic Equipment Components
Country: USA
NCB Code: 01

Thank you for taking an interest in the Circuit Breaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number G166010-1, an item that traces back to the manufacturer Raytheon Company. Listed with NSN 5925011596609, this listing is available for purchase from our website at any time. If you are interested in part number G166010-1 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Customer Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Note : We Will Not Share Your Information To Any Third Parties.

Upload RFQ SHEET

To make the part searching process as simple as possible, we choose to list offerings with as much relevant information as we can. For example, while part number G166010-1 is manufactured by Raytheon Company, it is specifically listed along with CAGE Code 49956. With this identifier, you can trace this item back to the exact facility it was sourced from. Additionally, with the NSN 5925-01-159-6609, this signifies that the product belongs to the Federal Supply Class 5925 Circuit Breakers. Alongside our easy-to-navigate database, we also offer highly competitive pricing and rapid lead times for the benefit of our customers. Get in touch with an industry expert today and see why so many customers steadily depend on us for their operational needs. 

NSN Information for Part Number G166010-1 with NSN 5925-01-159-6609, 5925011596609

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-159-6609

Item PartTypeName:

CIRCUIT BREAKER

59250115966090P
CIICHCCESDPMICCriticalityENAC
UA
Part NumberISCRNVCRNCCHCCMSDSSADC
CD4-Z160-1595

Characteristics Data of NSN 5925-01-159-6609, 5925011596609

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ABTDMOUNTING SLOT WIDTH0.164 INCHES NOMINAL
ADAQBODY LENGTH5.844 INCHES NOMINAL
ADATBODY WIDTH3.096 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.546 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.032 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.750 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.032 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.218 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.609 INCHES NOMINAL
AKPXPOLE QUANTITY4
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE AND 8 SLOT
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE60.0 AMPERES AC FOURTH LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE60.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE60.0 AMPERES AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS107.0 DC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC FOURTH LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC FOURTH LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT FOURTH LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SECOND LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEUNDERVOLTAGE FIRST LOCATION
CPRJTRIP RELEASE METHODMAGNETIC FIRST LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC FOURTH LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC SECOND LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC THIRD LOCATION
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS FIRST LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY FOURTH LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SECOND LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY THIRD LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT140.0 FOURTH LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT140.0 SECOND LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT140.0 THIRD LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY4 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE,TWO,THREE,AND FOUR LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT FOURTH LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CWJKCASE MATERIALPLASTIC
FEATSPECIAL FEATURESFOUR TERMINALS ON POLE ONE
FREQFREQUENCY IN HERTZ400.0 FOURTH LOCATION
FREQFREQUENCY IN HERTZ400.0 SECOND LOCATION
FREQFREQUENCY IN HERTZ400.0 THIRD LOCATION
TESTTEST DATA DOCUMENT49956-G166010 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY10 THREADED STUD