Thank you for taking an interest in the Power Supply NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number G254084-1, an item that traces back to the manufacturer Raytheon Company. Listed with NSN 6130011833927, this listing is available for purchase from our website at any time. If you are interested in part number G254084-1 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-183-3927 Item PartTypeName: POWER SUPPLY | 6130 | 011833927 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
G254084-1 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 16.600 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 7.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | SALT SPRAY PROOF |
AGAV | END ITEM IDENTIFICATION | ALQ184 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 200.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT64.0 DC VOLTS NOMINAL 2ND OPERATING POWER RQMT28.0 DC VOLTS NOMINAL 3RD OPERATING POWER RQMT15.0 DC VOLTS NOMINAL 4TH OPERATING POWER RQMT5.0 |
APPA | OUTPUT VOLTAGE RATING | 6.3 AC POUNDS PER HOUR DRY 1ST POWER OUTPUT AND 6.6 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST POWER OUTPUT-3.9 DC MINOR DRY 2ND POWER OUTPUT AND-3.896 DC MINOR WITH RETAINING CHAIN 2ND POWER OUTPUT1.69 DC MINOR DRY 3RD POWER OUTPUT AND 1 |
APTQ | INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 55.0 KILOHERTZ NOMINAL 1ST POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -54.0/71.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 1.1 AC AMPERES NOMINAL 1ST POWER OUTPUT2.0 DC MILLIAMPERES MINIMUM 2ND POWER OUTPUT AND 3.0 DC MILLIAMPERES MAXIMUM 2ND POWER OUTPUT108.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND 109.0 DC MILLIAMPERES MAXIMUM 3RD POWER OUTPUT |
CWGN | OUTPUT PHASE | SINGLE 1ST POWER OUTPUTSINGLE 2ND POWER OUTPUTSINGLE 3RD POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 0.2 VOLTS RMS 2ND POWER OUTPUT AND 1.6 VOLTS RMS 2ND POWER OUTPUT1.0 VOLTS RMS 3RD POWER OUTPUT AND 10.0 VOLTS RMS 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 1ST POWER OUTPUT8 2ND POWER OUTPUT8 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE 1ST POWER OUTPUTCONNECTOR,RECEPTACLE 2ND POWER OUTPUTCONNECTOR,RECEPTACLE 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 15.0 AC AMPERES MINIMUM 1ST OPERATING POWER RQMT AND 22.0 AC AMPERES MAXIMUM 1ST OPERATING POWER RQMT1.2 DC AMPERES NOMINAL 2ND OPERATING POWER RQMT1.5 DC AMPERES NOMINAL 3RD OPERATING POWER RQMT0.25 DC AMPERES NOMINAL 4TH OPERATING POWER R |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
FEAT | SPECIAL FEATURES | OUTPUT VOLTAGES AND CURRENT ARE GIVEN FOR OPERATING ONE TWT. THIS POWER SUPPLY OPERATES 8 DIFFERENTTWTS. OVERCURRENT PROTECTION CIRCUIT,RELAY RESET WHEN POWER IS CYCLED ON AND OFF. |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | SOURCE CONTROLED |