Thank you for taking an interest in the Transformer Pulse NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 19332, an item that traces back to the manufacturer Robert M Hadley Company Inc. Listed with NSN 5950013360229, this listing is available for purchase from our website at any time. If you are interested in part number 19332 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-336-0229 Item PartTypeName: TRANSFORMER,PULSE | 5950 | 013360229 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
841327-0001 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABMK | OVERALL WIDTH | 2.000 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 0.005 SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 197.96 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
ACZB | FREQUENCY RATING | 33.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CRGS | DC RESISTANCE RATING IN OHMS | 0.300 SINGLE COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 30.000 SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 19.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.100 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.870 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 0.24 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 36.27 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TEST | TEST DATA DOCUMENT | 13973-841327 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 8 TURRET |